Puremind Fixed Frequency Cooling&Heating Split Air Conditioner 9000BTU

$200.00

  • Smart Air Flow
  • Safety First Design
  • Long Distance Air supply
  • Auto Restart
  • Self-clean
  • Self-diagnosis
  • Sleep Mode
  • Remote Control
Bulk deal
QuantityFixed price
5 - 99$200.00
100 +$199.00
WhatsApp Inquiry
×

Specification

Model9000BTU
Typecooling&heating
Control typeremote
Power supply208-230V~/60Hz/1P
Rated Cooling
(95F/35C)
Rated cooling capacityBtu/h9000
EERBtu/W.h11
SEERBtu/W.h19
Rated Heating
(47F/8.3C)
Rated Heating capacityBtu/h10000
HSPF Rating (Region IV)Btu/W.h10
COPW/W3
COP (5℉/-15℃)W/W1.95
Input ConsumptionCoolingW810
HeatingW970
Rated CurrentCoolingA3.6
HeatingA4.4
MXimum Operation PressurePSIG650
MXimum Fuse SizeA15
Moisture removalLiters/h1.1
Indoor noise level at coolingTurbo/High/Med./Low/Mute 38/35/32
Outdoor noise leveldB(A)50
Connecting PipeGasinches3/8''
Liquidinches1/4''
Connecting WiringSize x Core number4×16AWG
Suitable aream245277
Net dimensions (W x D x H)Indoormm811x292x205
inch31.92x11.49x8.07
Outdoormm715x290x498
inch28.14x11.42x19.61
Net weightIndoorkg/Ibs9/19.8
Outdoorkg/Ibs24.5/54.1
Indoor Packing dimensions (W x D x H)mm885x366x278
inch34.84x14.40x10.94
Outdoor Packing dimensions (W x D x H)
(without pipe)
mm818x325x538
inch32.20x12.80x21.18
Outdoor Packing dimensions (W x D x H)
(with pipe)
mm838x338x550
inch33.00x13.31x21.65
Gross weight (without pipe)Indoorkg/Ibs11/24.2
Outdoorkg/Ibs27/59.5
Gross weight (with 5m pipe)Outdoorkg28.5
OutdoorIbs63
Loading Capacity (IN+OUT)40’HC (without pipe)285
Loading Capacity (IN+OUT)40’HC (with pipe)256
Loading Capacity (IN)40’HC/ 40'GP/ 20'GP718/638/302
Loading Capacity (OUT)40’HC/ 40'GP/ 20'GP(without pipe)400/400/196
Loading Capacity (OUT)40’HC/ 40'GP/ 20'GP(with pipe)360/358/167
*** Indoor Unit ***  
Indoor MotorMotor Brand Weilling/Broad-Ocean
Motor Model(Factory Code) AC
Indoor air circulation/Him3/h600
  CFM350
Evaporator mmΦ7x2
*** Outdoor Unit ***  
Compressor Brand GMCC
Compressor Model ASN98D32UEZ
Outdoor MotorMotor Brand Weilling/Broad-Ocean/SHIBURA
Motor Model DC
Outdoor air circulation/Him3/h1880
  CFM1110
Condenser mmΦ7x1
Factory Refrigerant charge(7.5m pipe)g/oz800g / 28.22ozs
Factory Precharge Line(m/ft)7.5 / 25
MXimum Line Length(m/ft)15 / 50
MXimum Height Difference Between Indoor and Outdoor(m/ft)10 / 33
Additional refrigerant charge(g/m, oz/ft)20 / 0.22
Operation temperature16~31
Ambinet temperatureIndoor(cooling/ heating)>=17/<=30
Outdoor(cooling/heating)-15~50/-25~30
Ambinet temperatureIndoor(cooling/ heating)F62.6~89.6/32~86
Outdoor(cooling/heating)F5~122/-13~86
Shopping Cart